Davey Tronic

  • Published on
    02-Dec-2015

  • View
    81

  • Download
    4

Embed Size (px)

Transcript

  • DAVEYTRONICDETONADOR ELECTRNICO DE LTIMA GENERACINJORNADAS DE TRONADURA 20002 Conferencia Ingenieros Explosivistas de Chile

  • DAVEYBICKFORD PLANTA DE PRODUCCIONHERYDetonadores,Cordn Detonante

  • PLANTA750 personnesProduction annuelle :10 millions de dtonateurs10 000 km de cordeau dtonantISO 9002 en 1995ISO 9001 en 1997Label CEAutres produits :Dtonateurs lectroniquesAllumeurs pour scurit automobileProduits spciaux pour l'arme et l'aronautiqueHERY

  • NITRO BICKFORD , area comercial de DAVEYBICKFORD NITRO BICKFORD en EUROPA

    BELGICAESPAAPORTUGALINGLATERRAITALIAALEMANIA

  • BANGLADESHPAKISTANINDONESIAMALASIATHAILANDIANITRO BICKFORD en el SUDESTE ASIATICO

  • NITRO-BICKFORD en AFRICA

    SENEGALGUINEACOSTA DE MARFILNIGERIACAMERUNGABONCONGOLA REUNION

    MARRUECOSTUNEZ

  • PROGRAMACION DE LOS DETONADORES

  • CONEXION DE LOS DETONADORES

  • CONEXION DE LOS DETONADORES

  • CHEQUEO DE LAS LINEAS

  • PROCEDIMIENTO DE CHEQUEO Y DISPARO

  • CARACTERISTICAS 1 a 4000 ms Precisin < 1 ms 1200 detonadores Comunicacin bidireccional Chequeo completo Desactivacin automtica No responde a sistemas ajenos

  • APORTES DEL SISTEMA DAVEYTRONIC CONFIABILIDAD SEGURIDAD PRECISION FLEXIBILIDAD

  • CONFIABILIDADDIALOGO CON LOS DETONADORES

  • CONFIABILIDADCHEQUEO DE LA LINEA???

  • SEGURIDAD

  • Pruebas de comportamiento de detonadores ante tormentas elctricas.Comportamiento ante corrientes vagabundas y tormentas elctricas : pruebas en condiciones extremas.Medicin de corrientes generadas por la descarga de un rayo en el suelo durante tormentas ; comparacin del comportamiento de detonadores electricos tradicionales, de detonadores no elctricos y de detonadores electrnicos Daveytronic. Los detonadores fueron dispuestos alrededor de un pararayos destinado a conducir las altas corrientes hacia el suelo.

  • Pruebas de comportamiento de detonadores ante tormentas elctricas.Para los detonadores elctricos tradicionales : Una linea en circuito abierto con 7 detonadores, colocada en forma de bucle encerrando una superficie de 2000 m2. Una linea en circuito cerrado con 7 detonadores, colocada en bucle encerrando una superficie de 2000 m2. Una linea en circuito cerrado con 7 detonadores, colocada en bucle encerrando una superficie de 1000 m2. Una linea en circuito abierto con 7 detonadores, colocada en linea, encerrando una superficie de ~0 m2 (bucle mnimo). Una linea en circuito abierto con 7 detonadores, colocada junta, encerrando una superficie de ~0 m2 (bucle mnimo) y con tres puntos de corte circuito.

  • Pruebas de comportamiento de detonadores ante tormentas elctricas.

    Para los detonadores no elctricos : Tres lineas de no elctricos Lineas en bucle

  • Pruebas de comportamiento de detonadores ante tormentas elctricas.Para los detonadores electrnicos Daveytronic :

    Una linea con 20 detonadores Daveytronic.

  • Pruebas de comportamiento de detonadores ante tormentas elctricas.RESULTADO :Durante la tormenta, se midi una corrienta mxima en el suelo de 39000 Amperes. 7 detonadores elctricos tradicionales colocados en bucle y en circuito cerrado detonaron. Los otros detonadores en circuito abierto no detonaron. Ninguno de los no elctricos deton. Ninguno de los electrnicos Daveytronic deton. 4 de los 20 no funcionaron ms despus de la prueba (sin respuesta al ser consultados por la Unidad de Programacin). El circuito electrnico quedo fuera de servicio.

  • CONCLUSIONESEl riesgo de detonacin accidental se confirm para los detonadores elctricos tradicionales. De acuerdo a lo esperado, los no elctricos no detonaron durante la prueba.Los detonadores Daveytronic no detonaron durante la prueba. El deterioro del circuito electrnico en varios de ellos muestra que el aislamiento del circuito de disparo del resto del circuito electrnico es eficaz.

  • PRECISION< 1 ms

  • CASTING

    Feuil1

    Tradicional30%

    Tronadura 137%+ 7 %

    Tronadura 245%+ 15%

    Feuil2

    Feuil3

  • FRAGMENTACION

    Chart1

    0.13

    0.0975

    Dig Time

    25% Reduction in Dig Time

    North

    Daveyfire , Inc.

    Daveytronic Testing

    Martin Limestone - Weaverland Quarry

    4th Level North Wall

    DateShot #Crush HRTruck CTTonskwhr, topkwhr, bottot kwhrkwhr/hrton/trkton/hrtons/kwhr

    6/7/9924-G3.5342340260105365104.368.8668.66.411

    6/8/9924-G5493385363141504100.869.1677.06.716

    6/9/9924-G9926479659257916101.870.4719.97.073

    6/10/9924-G9916592654252906100.772.4732.47.276

    6/11/9924-G7.572518252021573598.072.0690.97.050

    6/14/9924-G7.2575443849720570296.859.2612.16.322

    Totals41.3413.028416.0295311754128100.168.8688.96.884

    6/17/9926-I0.54260623294188.065.0520.02.766

    6/18/9926-I6.75673731516215731108.355.7552.75.104

    6/21/9926-I9855886655253908100.969.2654.06.482

    6/22/9926-I6.25594115474192666106.669.7658.46.179

    6/23/9926-I8.75875886652255907103.767.7672.76.490

    6/24/9926-I8.5825673672261933109.869.2667.46.080

    Totals39.8384.025551.0303112084239106.666.5642.86.028

    6/24/9927-J4.25412786329128457107.568.0655.56.096

    6/30/9927-J7.75755142627241868112.068.6663.55.924

    7/1/9927-J7.25714941613257870120.069.6681.55.679

    7/2/9927-J8.25805606622253875106.170.1679.56.407

    7/6/9927-J2.75272038293137430156.475.5741.14.740

    7/7/9927-J5.5493445488219707128.570.3626.44.873

    7/8/9927-J8765542644255899112.472.9692.86.165

    7/9/9927-J0.252134542983332.067.0536.01.614

    Totals32.0305.021706.0271411503864120.871.2678.35.617

    8/23/9939-Q3.53221872319632793.468.3624.96.688

    8/24/9939-Q9.592651967426794199.170.9686.26.928

    8/25/9939-Q8.75945974628266894102.263.6682.76.682

    8/26/9939-Q882502854422977396.661.3628.56.505

    8/27/9939-Q8855738602256858107.367.5717.36.688

    8/30/9939-Q5.548334238516254799.569.6607.66.110

    Totals43.3433.028788.0306412764340100.366.5665.66.633

    9/8/9936-R2.52416371506221284.868.2654.87.722

    9/9/9936-R880555054222176395.469.4693.87.274

    9/10/9936-R8.577561858325483798.573.0660.96.712

    9/13/9936-R8.584569558724583297.967.8670.06.845

    9/14/9936-R991631361724986696.269.4701.47.290

    9/15/9936-R5.550358436415251693.871.7651.66.946

    Totals42.0406.028397.028431183402695.969.9676.17.053

    &CDaveytronic TestingMartin Limestone-Weaverland4th Level North Wall Crusher &R

    South

    Daveyfire , Inc.

    Daveytronic Testing

    Martin Limestone - Weaverland Quarry

    4th Level South Wall

    DateShot #Crush HRTruck CTTonskwhr, topkwhr, bottot kwhrkwhr/hrton/trkton/hrtons/kwhr

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    Totals0.00.00.00000.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    Totals0.00.00.00000.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    Totals0.00.00.00000.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    Totals0.00.00.00000.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    00.00.00.00.000

    Totals0.00.00.00000.00.00.00.000

    Excavation

    NonelDtron

    Dig TimeDig Time

    0.120.1NonelDaveytronic

    0.130.11Dig Time0.130.0975

    0.110.12

    0.150.06

    0.140.09

    0.130.06

    0.11

    0.13

    0.0975

    Excavation

    Dig Time

    25% Reduction in Dig Time

  • VIBRACIONESImpedir el acoplamiento de detonaciones

  • PRECORTE EN MINERIA SUBTERRANEA3 Iniciacin instantnea

  • FLEXIBILIDAD t = 1 ms

  • FRAGMENTACION

  • VIBRACIONESInterferencia de ondasobjetivo : reducir velocidades de partculas de la onda ssmica.

  • FRECUENCIAS DE VIBRACIONES

  • Case study : AIRVAULT Quarry (near Poitiers), Calcia groupProblems in a specific area close to a village with classical electric detonators.Measured vibration peaks of 9 to 10 mm/s. serious complaints limited unit charge limited blast sizes Negative impact on productivity without solving the problem.Daveytronic tests :5 Daveytronic blasts in 19999 Daveytronic blasts in 2000

  • New initiation sequence8 ms16 ms24 ms32 ms

  • Electric blastDaveytronic blast

  • MINERIA SUBTERRANEAt1t2t3t4

  • DAVEYTRONIC NUEVA TECNOLOGIA DE INICIACION

  • Graph5

    3.03053846152.2332860106

    2.43938888891.9599968419

    2.00936842111.7836471478

    E2N4-s250

    2.01416666672.0306301859

    2.12668421051.7316898379

    2.6282.0056197024

    E5N3-s230

    2.2031.7665988864

    1.68218181821.7757165959

    1.8131.4604753846

    1.7721.5885297706

    1.75566666671.5385324496

    2.04235714291.6812929068

    2.2448751.7056613581

    1.74806251.6890809121

    2.011.595990566

    Actual Energy

    Theorical Energy

    Energy (MJ/m3)

    Energy - DMD Quarry

    Inc frt frg

    10.05384615380.3

    14.69444444440.0111111111

    11.06842105260.2684210526

    16.57142857140.9714285714

    8.4-0.2916666667

    13.42631578950.9368421053

    13.7650.02

    11.33333333330

    15.6789473684-0.1947368421

    15.14545454550

    13.66923076920.0384615385

    10.0875-0.025

    12.04666666670.1

    9.450.2928571429

    30.71250.05

    17.0187