计量泵metering pump dosing pump controlled volume pump; dosing pump; proportional pump; measuring pump

  • View
    227

  • Download
    6

Embed Size (px)

DESCRIPTION

metering pump dosing pump controlled volume pump; dosing pump; proportional pump; measuring pump

Transcript

  • Metering Pump

  • SMSM-ASM-BSM-CSM-DSM-ESM-FSM-G

    05

    06

    07

    08

    09

    10

    11

    SZ

    SM-A Hydralic Diaphragm Metering Pump

    SM-B Hydralic Diaphragm Metering Pump

    SM-C Hydralic Diaphragm Metering Pump

    SM-D Hydralic Diaphragm Metering Pump

    SM-E Hydralic Diaphragm Metering Pump

    SM-F Hydralic Diaphragm Metering Pump

    SM-G Hydralic Diaphragm Metering Pump

    SZ-ASZ-A1SZ-A2SZ-BSZ-CSZ-DSZ-ESZ-FSZ-G

    14

    15

    16

    17

    18

    19

    20

    21

    22

    SZ-A Plunger Metering Pump

    SZ-A1 Plunger Metering Pump

    SZ-A2 Plunger Metering Pump

    SZ-B Plunger Metering Pump

    SZ-C Plunger Metering Pump

    SZ-D Plunger Metering Pump

    SZ-E Plunger Metering Pump

    SZ-F Plunger Metering Pump

    SZ-G Plunger Metering Pump

    SJMSJM-ASJM-BSJM-CSJM-D

    SJM-A Diaphragm Pump

    SJM-B Diaphragm Pump

    SJM-C Diaphragm Pump

    SJM-C Diaphragm Pump

    25

    27

    29

    31

    Ammmonication Device

    Acid Squamous Salt Device

    Hydrazine Device

    Recycled Water Medicated Devices

    35

    36

    37

    38

    Contents

    39

    SM Hydralic Diapgrahm Metering Pump

    SZ Plunger Metering Pump

    SJM Diaphragm Pump

    Medicate Device

    Products Presentation

    Special requirements

    Special designs

    Special manufacturing

  • 50000/50MPa1%0-800mm2/s450oC

    Major Performance ParametersSingle-joint maxium flow: 50000 liters/hourMaxium discharge pressure: 50 MPaSteady state accuracy: 1%Media Viscosity: 0-800mm2/sTemperature of transporting media can reach over 450 degree centigrade

    SM

    GB/T7782-1996

    Main FeaturesDesigning and making standard GB/T7782-1996It can remove remained gas in the hydrolic and keep the oil stiff with high metering accuracy.Seal without leakingControl system of diaphragm is full retroposition supportIt can operate safely without any media in the pump headLubricating oil at the driving end is totally separated from hydrolic oil at the hydralic head.

    ApplicationsIt is suitable for the high pressure and large flow situation during the technique process of oi l , pertol ization and chemoindustry, or prying and loading system of dangerous chemicals injection and land gas transporting and marine oil and gas transporting, nuclear power and military industry as well as other key processes in environment protection, medication, paper making and food industry.

    SM HYDRALIC DIAPHRAGM METERING PUMP

    Positive stop

    discharge/pressurerelease valve

    automatic slippage system

    high-quality diapgrahm

    One-way check valve

    Plunger

    slippage valve

  • 03D39&EDUR&R&37)(

    Standard stainless steel hydralic endSingle-joint maxium flow: 50000 liters/hour, Maxium discharge pressure: 50 MPa, standard PVC hydralic endSingle-joint maxium flow: 50000 liters/hour, Maxium discharge pressure: 10 barInside composite safety valve can avoid excess pressure and discharging gas automaticallyMetering accuracy: 1%Temperature of transporting media can reach 150oC or 350oC under particular circumastancesDiaphragm PTFE can be easily installed without leaking problemsNewest technologies are applied to control automatic slippage, safe and reliableCrack detect of diaphragm pump (on-site/distance) can use either preesure type or electrolyte style.

    The First High-performance Diaphragm Pump

    Multiple standard hydralic ends include high-quality diapgrahm pump head and metal diaphragm pump headSpecial hydralic ends like insulation jacket are provided for choiceLeaking detect of diaphragm pump (on-site/distance) can use either preesure type or electrolyte style.Special choices are prepared for materials of pump head, one-way valve, diaphragm, plunger and stuffings Accessories are sufficience for choice like inlet and outlet one-way valve, single ball valve, two-ball valve and cone valve

    Hydralic end

    Compact structure and durableModel design, flexibly add or reduce accessoriesChangeable eccentric mechanism, ensuring a steady transporting pulseAccurate adjustment of effective stroke lengthAll motion parts are lubricated with long lifetimeParallel connection can be used among them with indivdual adjustment and controlFlow adjustment can be realized whether the machine is on or not by hand, electricity or frequency

    Driving end

    ---PPPVCPTFEPVDF304316316L

    37)( --

    Pump head material Diaphragm material---media ensuring that metering pump can transport various chemicals and materials: PPPVCPTFE

    PVDF304316316L stainless steel

    PTFE diaphragmMetal diaphragm can meet requirements of different techniquesHigh-accuracy one-way check valve system----ensure high accuracy of the metering pump

  • 5

    Parameters

    Install size

    SM-ASM-A Hydralic Diapgrahm Metering Pump

    Type

    L/hFlow

    MpaMaxium pressure '

    inlet pipe connections(D)&

    outlet pipe connections(C)Motor0.12kW

    Motor0.18kW

    SM-A-2/5 2 5 12()x3 12()x3SM-A-3.2/3.2 3.2 3.2 14()x3 14()x3SM-A-5/2.0 5 2.0 14()x3 14()x3SM-A-8/1.3 8 1.3 18()x3 18()x3SM-A-14/0.8 14 0.8 18()x3 18()x3SM-A-10/5 10 5 12()x3 12()x3SM-A-12.5/4 12.5 4 12()x3 12()x3SM-A-16/3.2 16 3.2 14()x3 14)x3SM-A-20/2.5 20 2.5 14()x3 14)x3SM-A-25/2 25 2 14()x3 14()x3SM-A-32/1.6 32 1.6 14()x3 14()x3SM-A-40/1.3 40 1.3 18()x3 18()x3SM-A-50/1.0 50 1.0 18()x3 18()x3SM-A-63/0.8 63 0.8 18()x3 18()x3SM-A-80/0.63 80 0.63 18()x3 18()x3SM-A-100/0.5 100 0.5 GB/T9119 DN15PN6RF GB/T9119 DN15PN6RF

    SM-A-125/0.4 125 0.4 GB/T9119 DN15PN6RF GB/T9119 DN15PN6RF

    SM-A-160/0.32 160 0.32 GB/T9119 DN15PN6RF GB/T9119 DN15PN6RF

    SM-A-200/0.25 200 0.25 GB/T9119 DN15PN6RF GB/T9119 DN15PN6RF

    0REHO A1 A2 B C DSM-A-2/5 169 169 126 12()x3 12()x3SM-A-3.2/3.2 186 186 134 14()x3 14()x3SM-A-5/2.0 182 182 138 14()x3 14()x3SM-A-8/1.3 190 190 139 18()x3 18()x3SM-A-14/0.8 194 194 142 18()x3 18()x3SM-A-10/5 169 169 126 12()x3 12()x3SM-A-12.5/4 169 169 126 12()x3 12()x3SM-A-16/3.2 186 186 134 14)x3 14()x3SM-A-20/2.5 186 186 134 14)x3 14()x3

    0REHO A1 A2 B C DSM-A-25/2 182 182 138 14()x3 14()x3SM-A-32/1.6 182 182 138 14()x3 14()x3SM-A-40/1.3 190 190 139 18()x3 18()x3SM-A-50/1 190 190 139 18()x3 18()x3SM-A-63/0.8 194 194 142 18()x3 18()x3SM-A-80/0.63 194 194 142 18()x3 18()x3SM-A-100/0.5 239 169 145 GB/T9119

    DN15PN6RFGB/T9119

    DN15PN6RFSM-A-125/0.4 239 169 145

    SM-A-160/0.32 239 169 145 GB/T9119 DN15PN6RF

    GB/T9119 DN15PN6RFSM-A-200/0.25 239 169 145

    &

    $$

    [ %PD[ '

    [

  • 6

    Parameters

    Install size

    SM-BSM-B Hydralic Diaphragm Metering Pump

    Type

    L/hFlow

    MpaMaxium pressure '

    inlet pipe connections(D)&

    outlet pipe connections(C)Motor0.37kW

    Motor0.55kW

    Motor0.75kW

    SM-B-5/16 5 16 14()x3 14()x3SM-B-9/10 9 10 14()x3 14()x3SM-B-15/6.3 15 6.3 18()x3 18()x3SM-B-18/16(6.3) 18 6.3 16 14()x3 14()x3SM-B-22/12.5(5) 22 5 12.5 14()x3 14()x3SM-B-25/4 25 4 18()x3 18()x3SM-B-32/10(4) 32 4 10 14()x3 14()x3SM-B-40/8(3.2) 40 3.2 8 14()x3 14()x3SM-B-40/2.5 40 2.5 DN15-PN6 RF GB/T9119 DN15-PN40 RF GB/T9119

    SM-B-50/6.3(2.5) 50 2.5 6.3 18()x3 18()x3SM-B-63/5(2) 63 2 5 18()x3 18()x3SM-B-80/4(1.6) 80 1.6 4 18()x3 18()x3SM-B-100/3.2(1.3) 100 1.3 3.2 18()x3 18()x3SM-B-125/2.5(1) 125 1 2.5 DN15-PN6 RF GB/T9119 DN15-PN40 RF GB/T9119

    SM-B-160/2(0.8) 160 0.8 2 DN15-PN6 RF GB/T9119 DN15-PN40 RF GB/T9119

    SM-B-200/1.6(0.63) 200 0.63 1.6 DN15-PN6 RF GB/T9119 DN15-PN40 RF GB/T9119

    SM-B-250/1.3 250 1.3 DN15-PN6 RF GB/T9119 DN15-PN40 RF GB/T9119

    SM-B-320/1 320 1 DN20-PN6 RF GB/T9119 DN20-PN40 RF GB/T9119

    SM-B-400/0.8 400 0.8 DN20-PN6 RF GB/T9119 DN20-PN40 RF GB/T9119

    SM-B-500/0.63 500 0.63 DN25-PN6 RF GB/T9119 DN25-PN6 RF GB/T9119

    SM-B-630/0.5 630 0.5 DN25-PN6 RF GB/T9119 DN25-PN6 RF GB/T9119

    SM-B-800/0.4 800 0.4 DN32-PN6 RF GB/T9119 DN32-PN6 RF GB/T9119

    SM-B-1000/0.32 1000 0.32 DN32-PN6 RF GB/T9119 DN32-PN6 RF GB/T9119

    $

    $

    [ '

    &

    PD[

    Type A1 A2 B C DSM-B-5/16 204 204 147 14()x3 14()x3SM-B-9/10 198 198 147 14()x3 14()x3SM-B-15/6.3 202 202 148 18()x3 18()x3SM-B-18/16(6.3) 204 204 147 14()x3 14()x3SM-B-22/12.5(5) 204 204 147 14()x3 14()x3SM-B-25/4 202 202 148 18()x3 18()x3SM-B-32/10(4) 198 198 147 14()x3 14()x3SM-B-40/8(3.2) 198 198 147 14()x3 14()x3SM-B-40/2.5 245 175 156 DN15-PN40 RF GB/T9119

    DN15-PN6 RF GB/T9119

    SM-B-50/6.3(2.5) 202 202 148 18()x3 18()x3SM-B-63/5(2) 202 202 148 18()x3 18()x3

    Type A1 A2 B C DSM-B-80/4(1.6)

    202 202 148 18()x3 18()x3SM-B-100/3.2(1.3)SM-B-125/2.5(1)

    239 169 155DN15-PN40 RF

    GB/T9119DN15-PN6 RF

    GB/T9119

    SM-B-160/2(0.8)SM-B-200/1.6(0.63)

    245 175 156SM-B-250/1.3SM-B-320/1

    248 198 165 DN20-PN40 RF GB/T9119DN20-PN6 RF

    GB/T9119SM-B-400/0.8SM-B-500/0.63

    266 216 179 DN25-PN6 RF GB/T9119DN25-PN6 RF

    GB/T9119SM-B-630/0.5SM-B-800/0.4

    272 252 179 DN32-PN6 RF GB/T9119DN32-PN6 RF

    GB/T9119SM-B-1000/0.32

  • 7

    Parameters

    Install size

    SM-CSM-C Hydralic Diaphragm Metering Pump

    Type

    L/hFlow

    MpaMaxium pressure '

    inlet pipe connections(D)&

    outlet pipe connections(C)Motor1.1kW

    Motor1.5kW

    SM-C-22/20(12.5) 22 12.5 20 18()x4 18()x4SM-C-28/20(10) 28 10 20 18()x4 18()x4SM-C-38/20(8) 38 8 20 18()x3 18()x3SM-C-48/16(12.5) 48 12.5 16 18()x3 18()x3SM-C-63/12.5(5) 63 5 12.5 18()x3 18()x3SM-C-80/10(4) 80 4 10 18()x3 18()x3SM-C-100/8(3.2) 100 3.2 8 DN15-PN5 RF GB/T9119 DN15-PN110 RFGB/T9116.1

    SM-C-125/6.3(2.5) 125 2.5 6.3 DN15-PN5 RF GB/T9119 DN15-PN110 RFGB/T9116.1

    SM-C-160/5(2) 160 2 5 DN15-PN5 RF GB/T9119 DN15-PN50 RF GB/T9116.1

    SM-